Home/Services

Three disciplines, one engineering team.

The engineer who prepares the coordination study is in the same team as the engineer who verifies the scheme on site. That is the whole point of how we're organised.

Voltage classes we work at

From 33 kV panels
to 765 kV GIS.

Every class below is work we've actually executed — not a capability statement. The higher you go, the fewer contractors can hold the schedule. We hold it.

33kV

Panel and switchgear testing on industrial and mining networks. Failure investigation on distribution systems.

66kV

Substations executed for a state transmission utility.

220kV

O&M of pooling substations evacuating utility-scale renewable generation.

400kV

Substation and GIS testing across multiple states, including interstate transmission projects.

765kV

GIS testing and commissioning — the highest voltage class on the Indian grid.

Resources

The instruments
we own.

Most contractors write "state-of-the-art equipment from reputed brands." Here is the actual list. It answers the question a technical evaluator is really asking — whether we can execute your scope with our own resources, or will be hiring instruments when the shutdown window opens.

InstrumentMake & modelUsed forCalibration
Primary injection setmake / modelCT saturation, primary current testscal. status
Secondary injection / relay test setmake / modelRelay calibration, scheme verificationcal. status
Circuit breaker analysermake / modelBreaker timing, travel, DCRMcal. status
CT / VT analysermake / modelRatio, polarity, burden, magnetisationcal. status
Tan delta / capacitance kitmake / modelInsulation condition of bushings and CTscal. status
Insulation resistance testermake / modelIR and polarisation indexcal. status
Winding resistance metermake / modelTransformer winding resistancecal. status
Turns ratio testermake / modelRatio and vector groupcal. status
Earth resistance testermake / modelEarth mat and electrode resistancecal. status
Thermal imaging cameramake / modelHot-spot detection during O&Mcal. status
SF6 gas analyser / handlingmake / modelGIS commissioning and maintenancecal. status

Calibration certificates are issued against traceable standards and travel with the crew to site. Certificates for any listed instrument are available on request.

Resources

People on the ground.

Utilities ask for this at pre-qualification anyway. Stating it up front saves a round of correspondence.

DisciplineStrength
Testing & commissioning engineerscount
O&M engineers and shift engineerscount
Protection & system studies engineerscount
Field technicianscount
Total deployable strengthcount

Who we work for

Utilities, PSUs
and EPC majors.

Our work reaches the grid through the contractors and developers who build it, and directly through the transmission companies who own it. Client names and project references are provided on request, subject to their consent.

State transmission utilities
Central transmission PSUs
EPC contractors
Interstate transmission licensees
Renewable energy developers
Industrial & mining operators
International engineering firms

Tell us what needs testing, running or solving.

Send us the voltage class, location and equipment schedule. We'll come back with a view on approach, mobilisation and commercials.